Screw tapping machine Gongsu Machine operating instructions

Thread size Size Test plate thickness Test plate thickness Axial load Test time Drill-drive time Screw speed under load Drill speed Rpm d mm kgf N Sec(Max) Min-1 ST2.9 0.7+0.7=1.4 15.3 150 3 1800 to 2500 ST3.5 1+1=2 15.3 150 4 1800 to 2500 ST3.9 1+1=2 15.3 150 4.5 1800 to 2500 ST4.2 1.5+1.5=3 25.5 250 5 1800 to 2500 ST4.8 2 +2=4 25.5 250 7 1800 to 2500 ST5.5 2+3=5 35.7 350 11 1000 to 1800 ST6.3 2+3=5 35.7 350 13 1000 to 1800 Clamping Machine Gongsu Machine Instruction Manual Jiaxing Honghai Measuring Instruments Co., Ltd. provides test equipment for measuring the self-tapping capability of screws. The quality of the screws is determined by the time that the screws penetrate the test board. This product can measure "test time", "instantaneous speed", "great speed" and "large run time" in the work of standard parts. And print and save the data. This product has a compact structure, strong features, high reliability, is an essential test equipment for the production of standard parts. one. This product step instructions: (Please refer to the following schedule) 1. Insert the 220V power supply before turning on the power, and turn the main power switch on the panel to the “ON” position to indicate that the instrument has been powered on normally (this state is hereinafter referred to as “standby state”). The LED display window displays "00" and "00.00", where the left two bits indicate the number of tests and the right four bits indicate the time value after the round of operation. When working, first place the workpiece to be tested on the designated workstation, and then press the “start” button on the panel. At this time, the instrument starts to work. At this time, on the LED window, the left four digits show the instant speed in operation. The four digits on the right indicate the time spent in the instrument's immediate operation. This state is hereinafter referred to as "operation state." After the instrument is operated, it will automatically stop according to the condition of the workpiece. The stop time is the measured parameter. It should be noted that there are two conditions that will stop automatically: 1) The instrument will stop at a certain point after the limit switch is actuated; 2) The instrument will set a certain limit time internally, and it will stop automatically when it reaches this time. If the limit time is set to "0", there is no limit time shutdown. Therefore, it can be correctly grasped according to needs during use. In the "standby mode", press the "switch" + "print" button at the same time, and then release it to display the current limit time, then press the "print" button to adjust the limit time, then press the "switch" button to restore to "standby mode". After the instrument is shut down, the LED window display returns to the "standby state", the number of times this round is displayed on the left, and the time used for the current round of operation is displayed on the right side. If you want to check the running speed of this round, press the “switch” key on the panel. At this time, the left side of the LED window shows four big speeds of this round, and the right four digits show the round of large running time. In order to work 50 times in succession (large), the print data of each 50 times is automatically printed. In addition, small time, large time, and average time can also be printed. If you do not need to wait 50 times before printing, you can press the "Print" button on the panel at any time. At this point, the data that was previously run is printed. After printing, the system automatically returns to the "ON state" and displays "00" and "00.00". . two. Parameter range: Running and storing times: 0 to 50 times (0 is “standby”) Running time: 0 to 99.98 seconds Resolution: 0.02 seconds Running speed: 0 to 3,000 revolutions/minute Resolution: 60 revolutions/minute limit time Setting: 0~15 seconds (If it is 0 seconds, it will not stop after the limit time expires.) The power supply of this product is 1000W. The single-phase three-wire system is used for the incoming line. The resistance of the grounding line is less than 4 ohms. Instrument size: 600mm wide × 300mm deep × 600mm high III. Attached Table: LED Display Window Schematic Table No. Description Left Window Four-digit Display Right Window Four-digit Display Units Unit of Contents Unit 1 After power-on, number of operations in “standby mode” (two-digit display) Second operation time Seconds 2 Press “ After the “Start” button is pressed, enter the “Operational State” Run Instantaneous Speed/Minute Running Time Seconds 3 In “Standby”, press “Switch” to check the speed of this round. Second Run Time Seconds 4 In “Standby”: Press the “Print” key to print the data runs (two-digit display) Second Run Seconds 5 In “Standby”: Press “Switch” + “Print” Key to check the limit time of stoppage. The front data is the limit time value Seconds Run time Seconds

Tungsten Carbide Ring For Pad Printing

Tungsten Carbide Ring,Pad Printing Tungsten Carbide Ring,Tampo Tungsten Carbide Ring ,Tungsten Carbide Rings

NINGBO KSION MACHINERY CO.,LTD , https://www.nbksc.com