How to use a multimeter to quickly find out where the electricity is leaking

With the gradual increase of rainy and wet weather, the fault repair of the cause of leakage has also increased. I believe that many electricians and friends are moving a lot of brains to find the cause of the leakage. So how can we use the multimeter to easily detect the cause of leakage?


Fault Finding Analysis  

Before analyzing where leakage occurs, we must first look at what faults occur in the home and what are the obvious characteristics; secondly, we must observe whether there are intuitional points of failure from the surface, and then conduct the next inspection.
1, first disconnect our power into the line of the total isolation switch, close all the user's electricity load, such as unplug the refrigerator, disconnect the pump switch.
2. Place the digital multimeter's gear on the 200M gear of the Ohm range. Place one test lead on one of the two outgoing wires on the load side. The other pen touches the wall. It is best to touch the ground wire or temporarily. Ground wire. After the number displayed on the multimeter is stable, the value of the insulation resistance of the main line is read. If the value of the insulation resistance is less than 0.5 megohms, then the main line has a problem. If the insulation resistance is above 0.5 megohm, it can be eliminated. There is a problem with the main line. Use the same method to measure another wire and check the value to see if there is a problem with the main line.
3. Check the insulation resistance value of the shunt and each electrical appliance, and use the same method to detect one by one until you find the fault point.


Handling Precautions 1. When using the 200M block of the multimeter's ohmic block, note that you cannot touch the metal parts of the meter when you measure, as that will make the reading inaccurate.
2. When measuring each electrical equipment, pay attention to discharge first to prevent the capacitive current in the electrical equipment from hurting people.
This method is a safer way to find the point of failure without power. This method is also suitable for the search for power leakage in power users and buildings. However, when searching, it is necessary not only to disconnect the power supply line, but also to disconnect the neutral line to avoid electric shock accidents. This article is for reference only! Non-professional electricians should not operate casually!

Injection Molding Machine For Pet Bowl

Pet bowl, Maidao injection molding machine provides customers with a more environmentally friendly injection molding machine production program.

Different from the injection molding machine with variable pump and fixed pump, the energy-saving injection molding machine uses the servo drive to realize the motor stops working when the machine does not move. Every time a different action is made, the corresponding power is used to provide power. It is not as good as the machine does not move. The servo motor will also stop completely.

The molding cycle is shorter and the efficiency is higher. Thanks to the servo motor, it takes less time to start and stop each movement of the injection molding machine, and after the proportional valve is eliminated, the hydraulic leakage is reduced and the speed is faster.

3. The energy consumption of the motor is lower. Compared with the traditional asynchronous motor with an efficiency of about 80%, the efficiency of the servo motor of this equipment with the same power can reach more than 90%, which saves energy.


Injection Molding Machine For Pet Bowl,Pet Preform Making Machine,Injection Molding Machine For Plastic,Pet Injection Molding

Ningbo Rhea Machinery Co., Ltd. , https://www.mytao-global.com